SIPROTEC 5 is part of the new generation of incomparable modular, flexible, and intelligent digital field devices and offers a wide product range with modular elements for every application and requirement.
Function Groups
Function-Group Type Line _ SI5200
Function-Group Type Voltage/current 3-Phase _ SI5201
Function-Group Type Voltage/current 1-Phase _ SI5202
Function-Group Type Voltage 3-Phase _ SI5203
Function-Group Type Circuit Breaker _ SI5204
Function-Group Type Transformer diff _ SI5205
Function-Group Type Auto Transformer diff _ SI5208
Function-Group Type Motor diff _ SI5213
Function-Group Type Generator diff _ SI5215
Function-Group Type Capacitor Bank _ SI5218
Function-Group Type Capacitor Bank diff _ SI5219
Protection & Automation Functions
Power-system data _ SI5010
Abnormal frequency protection (ANSI 81AF) [FGs:] _ SI5091
Arc protection [Can be used in FGs that provide current measured values] _ SI5071
Automatic reclosing [FGs: Circuit-breaker] _ SI5024
Bus Coupler Differential Protection [Part of the Bay proxy] _ SI5107
Busbar differential protection for single busbar (ANSI 87B) [FGs:] _ SI5086
Busbar differential protection [FGs: Busbar] _ SI5100
Circuit breaker failure protection (1-Pole/3-Pole) [FGs: Circuit-breaker] _ SI5101
Circuit breaker failure protection (3-Pole) [FGs: Circuit-breaker] _ SI5102
Circuit breaker failure protection (ANSI 50BF) [FGs: Circuit-breaker] _ SI5062
Circuit breaker restrike protection [FGs: Circuit-breaker] _ SI5063
Current jump detection [Can be used in Protection FGs based on current measurement] _ SI5068
Differential protection for phase angle regulating transformer (PST) [FGs:] _ SI5074
Directional intermittent ground fault protection [FGs:] _ SI5035
Directional negative sequence protection with current independent time delay (ANSI 46) [FGs:] _ SI5037
Directional overcurrent protection, ground (ANSI 67N) [FGs: can be used in protection FGs] _ SI5078
Directional overcurrent protection, Phases (ANSI 67) [FGs: can be used in protection FGs] _ SI5027
Distance protection with classic method (ANSI 21, 21N) [Can be used in FGs that provide voltage and current measured values as well as line parameters] _ SI5015
Distance protection with reactance method (RMD) (ANSI 21/21 N) [Can be used in FGs that provide voltage and current measured values as well as line parameters] _ SI5014
Echo and tripping in the event of weak infeed [FGs: Line] _ SI5021
End fault protection in busbar protection [FGs: Circuit-breaker] _ SI5104
External trip initiation 3-Pole [FGs:] _ SI5023
External Tripping Busbar Section (Direct) [Busbar PF of the
Busbar FG] _ SI5105
External Tripping Busbar Section (from Bay) [FGs: Circuit-breaker] _ SI5106
Fault locator [Can be used in protection FGs with 3-phase current and voltage measurement] _ SI5051
Faulto lcator plus [Can be used in protection FGs with 3-phase current and voltage measurement] _ SI5052
Generator differential protection (ANSI 87G) [FGs:] _ SI5077
Ground fault protection for high resistance ground faults in grounded-neutral systems (ANSI 67N) [FGs: Line] _ SI5019
Group indications of overcurrent protection functions [FGs:] _ SI5030
Hot-spot calculation (ANSI 49H) [FGs:] _ SI5083
Impedance protection (ANSI 21) [Can be used in FGs that provide voltage and current measured values] _ SI5016
Inherent circuit breaker failure protection [FGs: Circuit-breaker] _ SI5103
Inrush-current and 2nd harmonic detection [Can be used in the same FG as the functions that are to be blocked] _ SI5065
Instantaneous high current tripping [FGs:] _ SI5029
Instantaneous tripping at switch onto fault [Can be used in all protection FGs] _ SI5058
Line differential protection (87L) [FGs: Line] _ SI5011
Load jam protection (Motor) [FGs: Motor] _ SI5098
Motor differential protection (ANSI 87M) [FGs:] _ SI5076
Motor restart inhibit (ANSI 66) [Can be used in specific protection FGs] _ SI5097
Motor starting time supervision (ANSI 48) [FGs: Motor] _ SI5096
Negative sequence protection (ANSI 46) [Cab be used in protection FGs with current measurement] _ SI5036
Non directional intermittent ground fault protection [Cab be used in protection FGs with current measurement] _ SI5034
Out of step protection (ANSI 78) [Can be used in an FG with at least 3 voltage inputs and current inputs] _ SI5064
Overcurrent protection 1-phase (ANSI 50N/51N) [Can be used in Protection FGs with 1-phase current measurement] _ SI5031
Overcurrent protection, Ground (ANSI 50N/51N) [Can be used in Protection FGs] _ SI5026
Overcurrent protection, Phases (ANSI 50/51) [Can be used in Protection FGs] _ SI5025
Overexcitation protection (ANSI 24) [FGs:] _ SI5079
Overfrequency protection (ANSI 81O) [Can be used in protection FGs, which are based on voltage measurement] _ SI5053
Overvoltage protection with 3-phase voltage (ANSI 59) [Can be used in protection FGs, which are based on voltage measurement] _ SI5039
Overvoltage protection with any voltage (ANSI 59) [Can be used in protection FGs, which are based on voltage measurement] _ SI5044
Overvoltage protection with negative-sequence voltage (ANSI 47) [Can be used in protection FGs, which are based on voltage measurement] _ SI5041
Overvoltage Protection with Negative-Sequence Voltage/Positive-Sequence Voltage [Can be used in protection FGs, which are based on voltage measurement] _ SI5081
Overvoltage protection with positive-sequence voltage (ANSI 59) [Can be used in protection FGs, which are based on voltage measurement] _ SI5040
Overvoltage Protection with Positive-sequence Voltage and Compounding (ANSI 59) [Can be used in protection FGs, which are based on voltage measurement] _ SI5042
Overvoltage protection with zero sequence voltage/residual voltage (ANSI 59N) [Can be used in protection FGs, which are based on voltage measurement] _ SI5043
Phase sequence switchover [It is integrated in the Power-system data] _ SI5057
Positive-sequence overcurrent protection (ANSI 50/51) [FGs:] _ SI5028
Power protection (P,Q), 3-phase (ANSI 32) [Can be used in FGs which provide measured voltages and currents of the 3-phases ] _ SI5066
Power swing blocking [Can be used in FGs with at least 3 voltage inputs and current inputs ] _ SI5017
Power-plant disconnection protection (ANSI 37 (-dP)) [FGs:] _ SI5084
Power-system data _ SI5010
Rate of frequency change protection [FGs:] _ SI5055
Rate of voltage change protection [Can be used in protection FGs with 3‑phase voltage measurement ] _ SI5048
Restricted ground fault protection (ANSI 87N, REF) [FGs: Transformer side , Auto transformer] _ SI5013
Restricted ground fault protection (ANSI 87N, REF) [FGs:] _ SI5075
Reverse power protection (ANSI 32R) [FGs:] _ SI5085
Rotor ground fault protection (1-3 Hz) [FGs:] _ SI5095
Rotor ground fault protection (IRgnd>, fn) (ANSI 64R) [FGs:] _ SI5093
Rotor ground fault Protection (Rgnd<, fn) [FGs:] _ SI5094
Sensitive ground fault detection [FGs:] _ SI5033
Shaft current protection (ANSI 51GN) [FGs: Voltage/current 1-phase] _ SI5099
Startup overcurrent protection (ANSI 51) [FGs:] _ SI5090
Stator ground fault protection 90 % [FGs:] _ SI5087
Stator ground fault protection 100 % (20 Hz) [FGs:] _ SI5088
Stator ground fault protection with 3rd harmonic [FGs:] _ SI5089
Stub differential protection (ANSI 87STUB) [FGs: Line] _ SI5012
Teleprotection with distance protection [Can be used in FGs with voltage-measuring point in combination with the distance-protection function ] _ SI5018
Teleprotection with ground fault protection [Can be used in FGs with a voltage-measuring point in combination with the Ground-fault protection function ] _SI5020
Temperature supervision [Can wok in all protection FGs] _ SI5061
Thermal overload protection 1-phase function (ANSI 49) [Can be used in 1-phase protection FGs with current measurement] _ SI5060
Thermal overload protection, 3-phase – advance (ANSI 49) [Can be used in 1-phase protection FGs with current measurement] _ SI5059
Thermal overload protection, user-defined characteristic curve (ANSI 49) [FGs:] _ SI5082
Transformer differential protection (ANSI 87T) [FGs:] _ SI5073
Tripping with missing or weak infeed according to French specification [FGs: Line] _ SI5022
Unbalanced-load protection [FGs:] _ SI5080
Undercurrent protection function (ANSI 37) [FGs:] _ SI5038
Underexcitation protection (ANSI 40) [FGs:] _ SI5092
Underfrequency load shedding [FGs: Voltage/Current 3-phase , Line] _ SI5056
Underfrequency protection (ANSI 81U) [Can be used in protection FGs, which are based on voltage measurement] _ SI5054
Undervoltage controlled reactive power protection (ANSI 27/Q) [Can be used in Protection FGs containing 3-phase voltage and current measurement] _ SI5067
Undervoltage Protection with 3-Phase Voltage (ANSI 27) [Can be used in protection FGs, which are based on voltage measurement] _ SI5045
Undervoltage protection with any voltage (ANSI 27) [Can be used in protection FGs, which are based on voltage measurement] _ SI5047
Undervoltage protection with positive-sequence voltage (ANSI 27) [Can be used in protection FGs, which are based on voltage measurement] _ SI5046
Undervoltage-controlled reactive-power protection (ANSI 27/Q) [FGs:] _ SI5049
Vector jump protection [Can be used in Voltage-current 3-phase & Voltage 3-phase FGs] _ SI5070
Voltage comparison supervision (ANSI 60) [FGs: Generator stator , Generator side , Voltage-current 3-phase , Transformer side , Auto transformer autoside] _ SI5050
Voltage dependent overcurrent protection (ANSI 51V) [FGs:] _ SI5032
Voltage jump detection [Can be used in Protection FGs based on voltage measurement] _ SI5069
Voltage measuring point selection [FGs:] _ SI5072